The SPE Library contains thousands of papers, presentations, journal briefs and recorded webinars from the best minds in the Plastics Industry. Spanning almost two decades, this collection of published research and development work in polymer science and plastics technology is a wealth of knowledge and information for anyone involved in plastics.
The SPE Library is just one of the great benefits of being an SPE member! Are you taking advantage of all of your SPE Benefits?
Amit S. Kulkarni , Srinivas Siripurapu , Todd M. Loehr , Parminder Agarwal , B. Parthipan , Pooja M.K., May 2010
Flame retardant (FR) PC/ABS blends find applications in the medical housings market owing to their superior processability and a fine balance between the primary requirements of flammability performance, mechanical properties and chemical resistance to hospital cleaners. In recent times, low part-surface gloss is emerging as an important requirement for such applications. This manuscript showcases a new chlorine-bromine free FR PC/ABS blend which meets these demanding requirements for extrusion and thermoforming applications.
B.R. Whiteside , R. Spares , P.D. Coates, May 2010
A system offering two different measurement methods for 3-dimensional evaluation of micromoulded surface features within a moulding process has been designed, manufactured and tested. The system adopts two methods for height measurement and subsequent 3D surface reconstruction. The first method, for feature sizes in the region 10?¬m to 2mm and non-optical surfaces, uses a local contrast technique to calculate when regions of the component come into focus and calculates surface heights accordingly. The second method, for the measurement of optically smooth, featureless surfaces, uses White Light Interferometry techniques to measure surface data. Both methods are seamlessly integrated into the system and require nothing more than a lens change to switch between the two.
R. Spares , B.R. Whiteside , P.D. Coates, May 2010
Micromoulding is a thermally dominated process.
Due to manufactured parts having high surface area to
volume ratios extremely high cooling rates are achieved.
Thermal measurements using surface mounted
thermocouples at comparable rates are impractical due to
their relatively high response times. To address this issue
an AGA 782 SW thermal imaging camera has been
modified such that it runs in a linescan mode and data are
collected using a high speed digitiser to allow capture
rates of 2500 lines per second. The rapid cooling of a
range of components and materials have been recorded
and the superheating of air traps within the component
have been observed.
Due to manufactured parts having high surface area to
volume ratios extremely high cooling rates are achieved.
Thermal measurements using surface mounted
thermocouples at comparable rates are impractical due to
their relatively high response times. To address this issue
an AGA 782 SW thermal imaging camera has been
modified such that it runs in a linescan mode and data are
collected using a high speed digitiser to allow capture
rates of 2500 lines per second. The rapid cooling of a
range of components and materials have been recorded
and the superheating of air traps within the component
have been observed.
R. Spares , B.R. Whiteside , P.D. Coates, May 2010
Micromoulding is a thermally dominated process.Due to manufactured parts having high surface area to volume ratios extremely high cooling rates are achieved.Thermal measurements using surface mounted thermocouples at comparable rates are impractical due to their relatively high response times. To address this issue an AGA 782 SW thermal imaging camera has been modified, such that it runs in a linescan mode and data are collected using a high speed digitiser to allow capture rates of 2500 lines per second. The rapid cooling of a range of components and materials have been recorded, and the superheating of air traps within the component have been observed
Martin N. Bureau, Marion Maire, Gerardo Diaz-Quijada, Lucie Robitaille, Abdellah Ajji,
Yahye Merhi, May 2010
End of Life Vehicles (ELVs) are becoming a growing concern because of their impact on the environment. The automotive industries are facing worldwide pressure to help find environmentally friendly ways of disposing end of life vehicles. Though most of the metal parts from the ELVs are recycled however, plastic components from the shredder residue are complex to separate and they are being mostly dumped into the landfill. The main purpose of this paper is to present an alternate solution to this environmental issue by using bio-degradable plastic in the automotives. Experimental works have been done to check the change in mechanical properties of bio-degradable plastic for accelerated weathering test. The results resemble the impact of weather on bio-degradable plastic while using for automotives in typical Australian environment.
Martin N. Bureau , Marion Maire , Gerardo Diaz-Quijada , Lucie Robitaille , Abdellah Ajji , Yahye Merhi, May 2010
Synthetic grafts from woven polyethylene terephthalate fibers or expanded polytetrafluoroethylene have been used for decades to replace diseased arteries. However, their thrombogenicity and low compliance (vs.arteries) inevitably lead to their occlusion. A need exists for new synthetic grafts with an anti-thrombogenic surface and high compliance to improve long-term patency. Grafts from nonwoven PET fiber structures obtained from melt blowing are evaluated. Contrary tocommercial woven Dacron ', they allow for mechanical compliance adjustment through control of fiber diameter, porosity and graft structure configuration. Their low thrombogenicity, when properly surface-treated using polyethylene glycol functionalization, artery-matching compliance and promising burst pressure are reported.
The use of gas-saturated pellets as a means to deliver a
controlled amount of blowing agent for foam extrusion was
investigated. Various PVC blend ratios of unsaturated
virgin and CO2 pre-saturated pellets were created before
placing into the hopper. It was found that PVC profiles
with a uniform microstructure can be produced. The blend
ratio is a critical process parameter as it governs the
amount of gas delivered to the process. Due to the high
solubility of CO2 at room temperature sub-critical
pressures can be used to saturate the PVC pellets. The
process was successfully carried out in an industrial R&D
lab and appears to be adaptable for large scale production.
Due to manufactured parts having high surface area to
volume ratios extremely high cooling rates are achieved.
Thermal measurements using surface mounted
thermocouples at comparable rates are impractical due to
their relatively high response times. To address this issue
an AGA 782 SW thermal imaging camera has been
modified such that it runs in a linescan mode and data are
collected using a high speed digitiser to allow capture
rates of 2500 lines per second. The rapid cooling of a
range of components and materials have been recorded
and the superheating of air traps within the component
have been observed.
S. Dimitrievska , J. Whitfield , S. A. Hacking , M. N. Bureau, May 2010
Bone loss around femoral implants used for total hip arthroplasty is a persistent clinical concern. In some cases, it may be caused by stress shielding, which is generally attributed to a mismatch in stiffness between the femoral implant and host bone. In this regard, a fatigue resistant, carbon fiber (CF) polyamide 12 (PA12) composite hip stem coated with hydroxyapatite (HA) for hip replacement has been developed to match bone stiffness and achievefixation by osseointegration. In vitro studies withosteoblast cells (MG63) showed no cytotoxicity of the composite components as seen by the cellular growth andcomposites interaction. In vivo studies comparing thecomposite and Ti-6Al-4V (Ti64) rods in the rabbit and rat femurs demonstrated significantly higher bone apposition to the composite than Ti64 rods. The results of this study indicate that the invasion of surrounding bone cells and thus osteointegration together with its bone-matching mechanical properties make the HA-coated CF/PA12 composite stem a promising hip replacement candidate.
Understanding the physical properties associated with
the gelation and fusion of a PVC plastisol will help to
improve process efficiency. Plastisol gelation and fusion
was characterized using both scanning electron
microscopy (SEM) and atomic force microscopy (AFM)
and compared to tensile properties developed at various
temperatures. Both SEM and AFM show good agreement
during the early stages of gelation. However AFM
continues to show particle boundaries during latter stages
of gelation and fusion that provide a more accurate
comparison with resulting tensile properties.
EC Brown, BR Whiteside, R Spares, PD Coates, May 2010
Plastics manufacturing is an interdisciplinary endeavor crossing chemical, mechanical, and electrical engineering as well as other fields. In this paper, a systems approach is described for the decomposition and development of a plastics manufacturing system. The case study involves the design, implementation, and validation of a thermal imprint lithography machine used in an undergraduate process control course. Its development motivated systems thinking about open and closed loop control, variances between theory and practice, performance measurement, and process optimization.
EC Brown , BR Whiteside , R Spares , PD Coates, May 2010
An ultrasonic measurement system has been
developed and operated in conjunction with a suite of
process monitoring transducers on a Battenfeld
Microsystem 50. Measurements are non-invasive;
piezoelectric sol-gel sensors can be integrated with the
mould and their low-profile nature is ideally suited to the
constraints of the micromoulding environment allowing
measurement of flow front position cooling dynamics
shrinkage morphology changes during solidification and
cycle repeatability. Ultrasonic measurements of mould
filling and cooling dynamics have been validated using
flow visualization techniques on the same machine.
EC Brown , BR Whiteside , R Spares , PD Coates, May 2010
An ultrasonic measurement system has been developed and operated in conjunction with a suite of process monitoring transducers on a Battenfeld Microsystem 50. Measurements are non-invasive; piezoelectric sol-gel sensors can be integrated with the mould and their low-profile nature is ideally suited to the constraints of the micromoulding environment, allowing measurement of flow front position, cooling dynamics, shrinkage, morphology changes during solidification and cycle repeatability. Ultrasonic measurements of mould filling and cooling dynamics have been validated using flow visualization techniques on the same machine.
Failure of plastic products is the result of the materialƒ??s behavior in the application but is also influenced by human factors such as material selection design processing and use. Material selection is critical to the success of a product. One of the greatest challenges relates to understanding chemical exposure in the application and the materialƒ??s corresponding resistance.Unsuitable chemical resistance of a material accounts for a majority of failures with a significant number involving exposure to secondary fluids. This paper will explore case studies that focus on chemical related failures as the result of improper material selection and understanding of secondary exposure conditions.
A L Kelly , B R Whiteside , T Gough , P D Coates, May 2010
The rheology of polymer melts has been measured at strain rates up to 107 s-1, relevant to micromolding and thin walled molding processes, using an instrumented high speed injection moulding machine. Deviations from shear thinning behavior were observed for commercial grades of polyethylene, polypropylene, polystyrene and PMMA, and shear thickening behavior occurred for some of the polymers examined. Off line parallel plate rheometry and twin bore capillary rheometry were used to provide rheological data at low and medium shear strain rates respectively. Measured shear viscosity was found to follow Newtonian behavior at low rates and shear thinning power law behavior at intermediate strain rates. At shear strain rates approaching or above 106 s-1, shear viscosity reached a rate-independent plateau, and in some cases shear thickened with further increase in strain rate. A relationship between the measured high strain rate rheological behavior and molecular structure was found, with polymers containing larger side groups reaching the rate independent plateau at lower strain rates than those with simpler structures. These results have implications for micromolding of particular polymer architectures.
Tim Gough, Ben R. Whiteside, Phil D. Coates, May 2010
Medical-grade polyvinyl chloride (PVC) was modified through a multistep physicochemical approach to yield a novel anti-adherent surface against potentially pathogenic bacteria. This was fulfilled via surface activation by coplanar surface dielectric plasma, followed by radical graft copolymerization of a spacer to render a well-defined polymer brush finally coated by biologically active species. Various surface probes together with in vitro biological assay were performed. Up to 85 % and 50% reduction in adherence degrees of gram-negative and positive strains were attained, respectively. Along with bacteria structural characteristics, wettability and surface topography of substrate were established to be principal parameters in adhesion.
Tim Gough , Ben R. Whiteside , Phil D. Coates, May 2010
The Microscale Polymer Processing: Applying the Tools (MUPP2) research programme aims to understand how molecular architecture influences processability of polymers, and the structures obtained through processing. Part of this programme involves micromoulding of a range of products, including those made from very highly controlled molecular architecture polymers (e.g. controlled MWD polystyrenes, PMMAs with nanocomposites), at a range of processing conditions. These products have been characterised using stress birefringence and polarised Raman spectroscopy to assess residual molecular orientation in conjunction with Small Angle Neutron Scattering (SANS) techniques. Experimental results indicate the variation in properties along small bar specimens. These results will be discussed, along with associated very small scale shear and extensional flow characterisations at lower strain rates
Atakan Altinkaynak, Mahesh Gupta, Mark A. Spalding, Sam L. Crabtree, May 2010
Biodegradable and biocompatible shape-memory polymer blends of soy protein (SP) and polyurethane (PU) based on poly(?æ-caprolactone) (PCL) has been synthesized using environmentally-friendly aqueous dispersion technique. High-pressure supercritical carbon dioxide (scCO2) foaming technique was applied to the blends to generate three-dimensional interconnected porous structures or scaffolds with special enhanced benefits for potential biomedical applications such as soft tissue engineering and/or drug release. Blending PU dispersion (PUD) with SP significantly increased the biocompatibility and biodegradability properties of the materials and improved their shape-memory capability. The PCL soft segment was found to be miscible with SP over the entire range of concentration as confirmed by DSC measurements, where a single Tg located between the Tg of the pure SP and PCL soft segment was observed for all blend concentrations. The shape-memory behavior of the blends was investigated for different concentrations under free-stress condition. The rate of strain recovery was found to be SP concentration dependent. The stress recovery of the blend reached a maximum value at wSP = 0.1 weight fraction. This finding was attributed to the maximum increase in the degree of crystallinity of PCLsoft segment at wSP = 0.1 as conformed by X-ray analysis.
Alex G. Zestos, Cole L. Grinnell, Long J. Vinh, Robert D. Pike, William H. Starnes, Jr., May 2010
Self-reinforced polypropylene composites are particularly appropriate for process-induced property gradation during the compression molding process. They react especially sensitive to temperature and pressure and can therefore cover a large gradation spectrum. With the help of a newly developed, differentially tempered compression mold, area-dependent thermal gradation is possible. The locally varying material properties yielded by compression molding can be optimally verified by instrumentalized impact experiments. The equivalents for stiffness (modulus of resilience) and strength (maximal force) can be determined, alongside energetic characteristic values like dissipative and storage work.
Alex G. Zestos , Cole L. Grinnell , Long J. Vinh , Robert D. Pike , William H. Starnes Jr., May 2010
Cone calorimetry studies showed that various metalexchanged
clays and zeolites containing only 3–4% of
Cu(II) Cu(I) Zn(II) or Al(III) were effective smoke
suppressants and fire retardants for plasticized PVC.
Copper(II)-Zn(II) and Cu(II)-Al(III) synergism for smoke
and heat reduction was observed with binary blends of the
clays and the effectiveness of the additives was usually
improved considerably by heating plasticizer-additive
mixtures under very high shear before combining them
with the polymer. Possible mechanisms of action of the
additives are discussed.
Alex G. Zestos , Cole L. Grinnell , Long J. Vinh , Robert D. Pike , William H. Starnes Jr., May 2010
Cone calorimetry studies showed that various metalexchanged clays and zeolites containing only 3'4% of Cu(II), Cu(I), Zn(II), or Al(III) were effective smoke suppressants and fire retardants for plasticized PVC. Copper(II)-Zn(II) and Cu(II)-Al(III) synergism for smoke and heat reduction was observed with binary blends of the clays, and the effectiveness of the additives was usually improved considerably by heating plasticizer-additive mixtures under very high shear before combining them with the polymer. Possible mechanisms of action of the additives are discussed
84 countries and 60k+ stakeholders strong, SPE
unites
plastics professionals worldwide – helping them succeed and strengthening their skills
through
networking, events, training, and knowledge sharing.
No matter where you work in the plastics industry
value
chain-whether you're a scientist, engineer, technical personnel or a senior executive-nor
what your
background is, education, gender, culture or age-we are here to serve you.
Our members needs are our passion. We work hard so
that we
can ensure that everyone has the tools necessary to meet her or his personal & professional
goals.
Any article that is cited in another manuscript or other work is required to use the correct reference style. Below is an example of the reference style for SPE articles:
Brown, H. L. and Jones, D. H. 2016, May.
"Insert title of paper here in quotes,"
ANTEC 2016 - Indianapolis, Indiana, USA May 23-25, 2016. [On-line].
Society of Plastics Engineers
Available: www.4spe.org.
Note: if there are more than three authors you may use the first author's name and et al. EG Brown, H. L. et al.